產(chǎn)品闡述
|
Single head system
|
General specifications
|
Sensing range
|
35
... 300 mm
|
Adjustment range
|
50
... 300 mm
|
Unusable area
|
0
... 35 mm
|
Standard target plate
|
100
mm x 100 mm
|
Transducer frequency
|
approx.
390 kHz
|
Response delay
|
approx.
30 ms
|
Indicators/operating means
|
LED green
|
Power
on
|
LED yellow
|
indication
of the switching state
flashing: program function object detected
|
LED red
|
solid
red: Error
red, flashing: program function, object not detected
|
Electrical specifications
|
Operating voltage
|
10
... 30 V DC , ripple 10 %SS
|
No-load supply current
|
≤
20 mA
|
Input
|
Input type
|
1
program input
operating distance 1: -UB ... +1 V, operating distance 2: +6 V ...
+UB
input impedance: > 4,7 kΩ program
pulse: ≥ 1 s
|
Output
|
Output type
|
1
switch output E4, NPN, NO/NC, programmable
|
Rated operating current
|
200
mA , short-circuit/overload protected
|
Default setting
|
Switch
point A1: 50 mm Switch point A2: 300 mm
|
Voltage drop
|
≤
3 V
|
Repeat accuracy
|
≤
1 %
|
Switching frequency
|
≤
13 Hz
|
Range hysteresis
|
1
% of the set operating distance
|
Temperature influence
|
±
1.5 % of full-scale value
|
Approvals and certificates
|
UL approval
|
cULus
Listed, General Purpose
|
CSA approval
|
cCSAus
Listed, General Purpose
|
Ambient conditions
|
Ambient temperature
|
-25
... 70 °C (-13 ... 158 °F)
|
Storage temperature
|
-40
... 85 °C (-40 ... 185 °F)
|
Mechanical specifications
|
Connection type
|
Connector
M12 x 1 , 4-pin
|
Protection degree
|
IP67
|
Material
|
|
|
Housing
|
brass, nickel-plated
|
|
Transducer
|
epoxy resin/hollow glass sphere mixture; foam polyurethane,
cover PBT
|
Mass
|
25
g
|